Multichannel Pipettors

RBO Multi-channel

8 and 12 channel micropipettes
  • Universal Tipcone – compatible with internationally accepted tips. Works best with Microlit Pipette Tips
  • Lightweight with soft grip for utmost user comfort
  • Fully autoclavable at 121° C, 15psi. for 10-15 mins
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit RBO Multichannel Micropipettes are high-precision micropipettes designed with ergonomics in mind, providing a remarkable user experience and impeccable accuracy in practical laboratory environments. As the best multichannel pipette available, it’s an ideal choice for scientists looking for reliable and precise tools.

The micropipette multichannel is offered in both 8 and 12 channels, making it a versatile option for various applications. This multichannel dispensing system is highly recommended for critical tasks such as ELISA (Diagnostic Test), Molecular Screening, Kinetic Studies, DNA Amplification, and more, ensuring efficiency and precision in every laboratory setting.

 

RBO Multi-channel: What’s in the box?

  1. Microlit RBO Multichannel Micropipette
  2. 3-4 compatible tips
  3. Calibration Tool
  4. Micropipette holder
  5. Calibration Certificate
  6. User guide
Features
Adjust Volume Easily with Plunger

Adjust Volume Easily with Plunger

The Plunger has been carefully designed with a high quality spring mechanism to ensure snag free and soft movement. Simply turn it to adjust the instrument’s volume comfortably.

Use Various Tips with a Universal Tipcone

Use Various Tips with a Universal Tipcone

A Universal Tipcone enhances the compatibility of the instrument and enables it to easily work with most of the internationally accepted standard tips.

Set the Volume with Perfection

Set the Volume with Perfection

A soft click sound at every increment ensures perfect volume setting and prevents any accidental changes. It also facilitates singlehanded operation.

Work with a Good Grip

Work with a Good Grip

A specially designed large Grippy provides good grip and great ease of use while operating.

Store Safely with a Holder

Store Safely with a Holder

The instrument includes a Holder that enables easy, efficient and safe storage.

Eject Tips with a Sequential Tip Ejector

Eject Tips with a Sequential Tip Ejector

A specially designed Sequential Tip Ejector and Tip Ejection Knob facilitate easy and effortless tip ejection, single-handedly.

Model No. Description Vol. Range(uL) Increment(uL) Accuaracy CV
+% +uL +% +uL
RBO-MCA-8/10 Multichannel Micropipette RBO Series 8-Channel Volume Range 0.5-10µL 0.5-10ul 0.02 1.6 0.16 1 0.1
RBO-MCA-12/10 Multichannel Micropipette RBO Series 12-Channel Volume Range 0.5-10µL
RBO-MCA-8/20 Multichannel Micropipette RBO Series 8-Channel Volume Range 2-20µL 2-20ul 0.02 0.8 0.16 0.4 0.08
RBO-MCA-12/20 Multichannel Micropipette RBO Series 12-Channel Volume Range 2-20µL
RBO-MCA-8/50 Multichannel Micropipette RBO Series 8-Channel Volume Range 5-50µL 5-50ul 0.1 0.8 0.4 0.4 0.2
RBO-MCA-12/50 Multichannel Micropipette RBO Series 12-Channel Volume Range 5-50µL
RBO-MCA-8/100 Multichannel Micropipette RBO Series 8-Channel Volume Range 10-100µL 10-100ul 0.2 0.8 0.8 0.3 0.3
RBO-MCA-12/100 Multichannel Micropipette RBO Series 12-Channel Volume Range 10-100µL
RBO-MCA-8/200 Multichannel Micropipette RBO Series 8-Channel Volume Range 20-200µL 20-200ul 0.2 0.8 1.6 0.3 0.6
RBO-MCA-12/200 Multichannel Micropipette RBO Series 12-Channel Volume Range 20-200µL
RBO-MCA-8/300 Multichannel Micropipette RBO Series 8-Channel Volume Range 40-300µL 40-300ul 0.2 0.8 2.4 0.3 0.9
RBO-MCA-12/300 Multichannel Micropipette RBO Series 12-Channel Volume Range 40-300µL

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-2.

What our Customers are saying

Liquid Handling Products Manufacturer

Dealer Opportunities

Microlit is your one-stop destination for precision liquid handling instruments: Micropipettes, Bottle Top Dispensers, Electronic Burettes, Pipette controllers, Pipette tips, and more. Experience the ease of streamlining your operations and enhancing your brand’s reach with Microlit’s comprehensive suite of offerings.

Product FAQs

Microlit micropipettes have a universal tip and are compatible with standard universal-fit tips. However, we recommend using Microlit ProTips for the best results.
The pipette is fully autoclavable at 121 C for 15-20 mins at 15 psi.
All pipettes are calibrated as per the ISO 8655 norms, which confirms the accuracy and precision of the liquid handling instruments. However, it is suggested to re-calibrate or get your pipette once in 6 months if it is used regularly.
Set the pipette at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the pipette is calibrated. If not, please follow the recalibration procedure in the instruction manual.
Yes, the pipette is supplied with few sample tips only. However, Microlit ProTips are available in racked, reloads, and bulk packaging for additional purchases.
As per the ISO 8655, it is recommended to get your pipette checked annually. However, based on the usage the pipettes can be re-checked every 3 or 6 months.
It is a good practice to pre-rinse the tip, especially while working with the liquids with high vapor pressure, and every time the tip is changed or the volume of the pipette is changed. Pre-rinsing reduces the capillary effect in low volume pipettes and it neutralizes the temperature of the tip with the sample in high volume pipette tips. Thereby, increasing the chances of the accuracy of an experiment.
The best technique for pipetting any viscous/foaming liquid is the Reverse Pipetting technique. To start with, set the desired volume and depress the plunger till the SECOND step. Immerse the tip inside the liquid and slowly release the plunger. Depress the plunger till the FIRST step only to get the desired volume. The residual (blow-out) volume is discarded. For different pipetting technique, please refer to the instruction manual.
Use of low retention tips is suggested while working with detergents, foaming liquids as well as viscous solutions. Due to its hydrophobicity and low adhesion property, the surface contact between the tip and liquid is less. Thereby, reducing the loss of valuable reagents. Please find Microlit ProTip™ low retention tips in the Tips section.
The design of 5ml and 10ml tip cones is different for each manufacturer and so universal-fit tips will not work. To ensure compatibility, please refer to Microlit ProTip™ low retention tips in the Tips section.